Explosion-protected mini-terminator for Foundation Fieldbus H1 and Profibus PA
R. STAHL's new, extremely compact type 9418 terminating resistor is suitable for explosion-protected FF H1 and Profibus PA installations. Two models for use in Zone 1 and Zone 21 are available: an Ex i terminator for intrinsically safe/FISCO fieldbus installations, and an Ex m model for power trunks that are not intrinsically safe combined with e.g. fieldbus barriers. Designed to fit in M20 cable glands, 9418 terminators can be very easily attached to cable entries, for instance in field distribution panels or field devices. Thus, users no longer need to seal unused cable entries with an otherwise required plug.
Fieldbus standards according to IEC 61158-2 call for the presence of a defined terminating resistor on both ends of a bus trunk as a measure to avoid signal reflections. While the power supply unit on one end of the bus will usually come with an integrated terminator, as is the case e.g. with R. STAHL's 9412 fieldbus power supply, the other bus end in the field must also be electrically terminated. Some devices typically found there, e.g. 9411 Ex i and Ex e field device couplers, feature built-in terminators for activation on demand. Others, such as
R. STAHL's new type 9413 digital I/O coupler, require a separate one like the new 9418 terminator if they are last in line on a fieldbus trunk.
More information...
Date 2009-09-29Ex i trip amplifier for SIL 2 applications |
|
Date 2009-09-29Modular UPS solutions for hazardous areas |
|
Date 2009-08-25Remote monitoring in hazardous areas via GPRS |
|
Date 2009-08-25Explosion protected WLAN access point for process plants |
|
Date 2009-07-23Power Supply - Integrated functions for physical layer diagnosis |
|
Date 2009-07-23WirelessHART gateway for wireless sensor/actuator networks |
|
Date 2009-06-22CCTV solutions featuring full control system integration |
|
Date 2009-06-22Field device coupler for zone 2 fieldbus applications |
|
Date 2009-05-22New user-friendly switch disconnectors for 40, 63 and 80 A |
|
Date 2009-04-20Ethernet-compliant new generation Ex-Remote HMIs |
|
Date 2009-04-20New Fieldbus Power Supply System for FF H1 segments |
|
Date 2009-03-19System solutions for explosion-protected equipment |
|
Date 2009-02-10HMIs with wide-ranging Industrial Ethernet support |
|
Date 2009-02-10Remote I/O system IS1 for zone 1 now FF HSE-enabled |
|
Date 2009-01-09Easy-to-handle, robust light for use in Ex zone 1 |
|
Date 2008-12-01Expanded Ethernet connectivity for Eagle operating systems |
|
Date 2008-12-01Ex i temperature transmitter for SIL 2 applications |
|
Date 2008-10-31Always the right Ex-Terminal Boxes |
|
Date 2008-10-31Turnkey surveillance systems for hazardous areas |
|
Date 2008-09-22Explosion proof connector |
|
Date 2008-09-22Explosion proof lighting |
|